| The
Ultimate engine control system for all V8, V10 & V12 engines |

|
|
X5
ENGINE CONTROL UNIT
|
| HARDWARE |
SOFTWARE
|
- Sequential
injection for 12 injectors
- 10
coil outputs
- 22
analog inputs
- 4
digital inputs (Hall or Magnetic)
- 4
switch inputs
- 4
Auxiliary control outputs l Dual internal NGK Lambda amplifiers
- 2
PWM Control (wastegates)
- Dual
K-Type thermocouple inputs
- DC
motor driver
- Dual
Knock control
- 2
MB internal data logger
- 2
RS232 interfaces (115,200 kbaud)
- 1
current loop interface
|
- User-friendly
software
- 3D
fuel and spark maps
- All
maps with adjustable breakpoints
- Programmable
sensor calibrations
- Closed
loop lambda control
- Unique
self-mapping software
- Fuel
and spark trims for each cylinder
- 3D
injection phase map
- Sensor
correction tables
- Closed
loop boost control (5 maps)
- Shift
without lift function
- Pit
lane speed limiter
- ECU
loadable with 2 calibrations
- Adjustable
internal logger sample rates
|
| APPLICATIONS:
|
|
Indy
Racing League, Sports
Cars
|
|
X5
ECU Technical Specifications
|
|
SOFTWA RE
- 3D
fuel and spark maps
- All
maps with adjustable breakpoints
- Programmable
sensor calibrations
- Closed
loop lambda control
- Unique
self-mapping software
- Fuel
and spark trims for each cylinder
- 3D
injection phase map
- Sensor
correction tables
- Closed
loop boost control (5 maps)
- Shift
without lift function
- Pit
lane speed limiter
- ECU
loadable with 2 calibrations
- Adjustable
logger sample rates
|
OUTPUTS
- 12
injector drives
- 10
digital ignition outputs
- Wastegate
controls (2)
- DC
Motor
- 4
Auxiliary outputs
-
Lambda heater control
- Digital
tach output
- Data
link to data logger
- Expansion
box interface
|
DIGITAL
INPUTS
- Engine
speed
- Cam
position
- Front
wheel speed
- Rear
wheel speed
- Beacon
- Switches
(2)
|
|
|
ANALOG
INPUTS
- Throttle,
Battery, Airbox, ExBP, Air Temp, Water Temp, Oil Temp, G Box Temp,
Fuel Press, Oil Press, Dual NGK, Beacon, Lateral G, ECU Temp,
Vref, Mixture SW, Boost SW, Dual EGT, Dual Knock
|
DIAGNOSTICS
- Error
codes for all sensors and pickups
- Programmable
error thresholds
- Sensor
Min and Max values recorded
- Non-volatile
diagnostic memory
|
OPTIONS
- Up
to 2MByte internal datalogger
- Dual
lambda sensor option
|
|
| OPERATIONAL |
|
Enclosure
|
Billet
6061 Aluminum
|
|
Construction
|
CMOS
surface mount design
|
|
Environmental
|
EMI
O ring sealed
|
|
Connector
|
Mil-Spec
79 pin filter type
|
|
Dimensions
|
5.0"
x 4.5" x 1.6"
|
|
Weight
|
2.5
lbs
|
|
Power
Supply
|
8
to 20 volts transient I protected
|
|
Power
Consumption
|
8
watts @ 14 volts
|
|
Operating
Temp
|
-40
to + 85 deg C continuous
|
|
EMI
Protection
|
Exceeds
100 V/m > 1GHz
|
|